Technical Data

(a) SCINTILLATION DETECTORS

Nucleonix Systems offers wide range of NaI Scintillation Detectors of different sizes both with flat & well type crystals, to meet the requirements of wide range of users for Gamma ray spectrometry measurements.
Scintillation detectors offered include 1"x1" & 2"x2" NaI integral assemblies with built-in pre-amplifiers. These detector assemblies give excellent stability, superior performance & good resolution in the range of 8.0 to 9.5% for Cs-137. Scintillation detectors of other sizes can be offered against user specific requirements also. For teaching labs we recommned 1"x1" or 2"x2" NaI detector with this integral model.

Important Specifications
Detector Type
1. Flat/Well type NaI crystal
2. Crystal Sizes
3. Well Size (applicable for SD 152 W & Sd 153 W only)
4. Photo multiplier

5. Resulation (Better than)
6. Pre-amplifier
7. Gain (Approx.)
8. Noise (RMS. referred to input)
9. Operating Voltage
10. Out put
11. Output impedance
12. Power Requirement (Typical)
SD 151
1” x 1”
---

R6095 of Hamamatsu or its equivalent
8.5 %
Built - in
25
Less than 50 µV
600 to 900 V
Positive Tail Pulse
90 Ohms
-12V @ 12 mA
SD 152/Sd 152 W
2” x 2”
0.656” dia x 1.546” deep

EMI 9857 or 9266 or its equivalent

8.5 %
Built - in
25
Less than 50 µV
700 to 900 V
Positive Tail Pulse
90 Ohms
-12V @ 12 mA
(b) GAMMA REFERENCE STANDARD SET TYPE GS 290

Gamma Reference Standard Set Type: GS290 consists of a set of FIVE Gamma sources evaporated & sealed on 25mm dia x 5mm plastic disc covering SIX photopeak energies in the range of 3 to 5 micro curie. A reference chart for this is given below. The accuracy of these sources is in the range of +/-10%. All these dics sources are enclosed in a box made of acrylic sheet and supplied.


Gamma Isotope Energy Mev Nominal Activity Half life
Co-57 0.123 2-5 µci 273 Days
Ba-133 0.36 (Main) 2-5 µci 7.5 years
Cs-137 0.662 2-5 µci 30 years
Co - 60 1.17; 1.33 2-5 µci 5.3 years
Na-22 0.511; 1.280 2-5 µci 2.6 years
(c) FREE EXPERIMENTAL BOOK LET : A booklet called "Experiments with Gamma Ray Spectrometer" will be supplied with each Gamma Ray Spectrometer kit, when you purchase. This illustrates in details about the experiments that can be done using this kit. Each experiment write-up contains, list of items required, experimental procedure, experimental data, analysis & computations, graphs etc.

 