Home AboutUs Products services news&events Dealers Education contactus
STATE OF ART INSTRUMENTATION FROM AN INNOVATIVE COMPANY
POWER SUPPLY UNIT - [ Type : PS 401H ]  
Technical Data

Power Supply PS401H has been exclusively designed for delivering higher power outputs upto a maximum of 200 Watts. This has additionally +/-6V DC at 7.5A in addition to the other low voltage outputs as given by PS401. It is designed to mate with the Standard Instrumentation Bin IB401. Both rack mounting and table top arrangements are possible. The LV supplies given out by this power supply are highly stable, with good regulation and low ripple.

Features

  • Output rating 200 watts
  • Generates +/-6V D.C @7.5 amps, +/-12V D.C @3 amps and +/-24V D.C @1.5 amp
  • Noise & ripple : 10mV for +/-6V, +/-12V & +/-24V
  • Regulation better than +/-0.05% for +/-12V & +/-24V and +/-0.1% for +/-6V
Specifications
Input Voltage
230V AC, single phase 50Hz with 10% variation in input voltage range
Frequency
50Hz + or - 3Hz
Current
1.5A @ 200W output .
DC output
+/-6V DC @7.5A
+/-12V DC @3A
+/-24V DC @1.5A
Total combined load not to exceed 200W
AC output
Voltage : 230V AC
Frequency: 50Hz +/-3Hz
Current : 0.5 amp (max)
Regulation
for +/-12V & 24V +/-0.05% (total band 0.1%), for +/-6V +/-0.1% (total band 0.2%), Over the combined range of zero to full load and specified mains variation, for measurements made within 1 min.period.
Stability
for +/-12V and +/-24V is +/-0.3%, for +/-6V is +/-0.6% over any 24 hrs period at constant ambient temperature. Over the combined range of no load to full load and specified mains variation after 60 min. warmup.
Temperature Range
0 to 50 deg. C ambient.
Temperature Coefficient
0.02% per deg. C over 0 to 50 deg. C ambient.
Noise & Ripple (rms)
Less than 10mV for all supplies
Recovery Time
+/-12V and +/-24V outputs will recover within +/-0.1% and +/-6V outputs will recover within +/-1% of steady state value within 1000 micro seconds following any change in specified line voltage or between 10 to 100% full load.
Plot No.162 A & B, Phase-II, IDA, Cherlapally, Hyderabad-500051 India Phone: +91-7207034546, +91-7331104481, 7331104482, Fax : 040 - 29706486.