Power Supply Unit *

Power Supply Unit * [ TYPE : PS 401H ]

Technical Data
manual
Features
Specifications
Input Voltage 230V AC, single phase 50Hz with 10% variation in input voltage range
Frequency 50Hz or – 3Hz
Current 1.5A @ 200W output .
DC output +/-6V DC @7.5A +/-12V DC @3A +/-24V DC @1.5A Total combined load not to exceed 200W
AC output Voltage : 230V AC Frequency: 50Hz +/-3Hz Current : 0.5 amp (max)
Regulation for +/-12V & 24V +/-0.05% (total band 0.1%), for +/-6V +/-0.1% (total band 0.2%), Over the combined range of zero to full load and specified mains variation, for measurements made within 1 min.period.
Stability for +/-12V and +/-24V is +/-0.3%, for +/-6V is +/-0.6% over any 24 hrs period at constant ambient temperature. Over the combined range of no load to full load and specified mains variation after 60 min. warmup.
Temperature Range 00 to 500C ambient.
Temperature Coefficient 0.02% per 0 over 0 to 500C ambient.
Noise & Ripple (rms) Less than 10mV for all supplies
Recovery Time +/-12V and +/-24V outputs will recover within +/-0.1% and +/-6V outputs will recover within +/-1% of steady state value within 1000 micro seconds following any change in specified line voltage or between 10 to 100% full load.