Inside Cyclotron Vault
1. Area Gamma Monitor (NXG_AGM) :
Area Gamma Monitor Type NXG_AGM, manufactured & supplied by Nucleonix Systems is primarily
designed to indicate dose rate in the measuring unit selected and produce audio / visual alarms, if
the dose rate exceeds preset value. By default, the unit is set to be in mR/hr & the range is (0.01 – 100
mR/hr). It uses latest state-of-art electronic devices including SoC based on ARM cortex A5
400MHz CPU with associated peripheral devices and other discrete ICs & components. Use of
these devices makes it compact & highly reliable. Powerful embedded code adds-up and enhances
its performance and gives extra advantage from the angle of fault diagnostics, programmable
features, measurement of dose rate & data communication under networked environment.
NXG_AGM3 is recommended with a range of (0.01 – 1R/hr) or (0.01 – 10R/hr), for monitoring dose
rates inside Cyclotron vault.
2. Neutron Area Monitor (NXG_NAM) :
This is required to monitor the Neutron flux / dose rate at just inside wall of the Cyclotron Vault.
For this,we recommend Neutron Area Monitor with an external detector probe (Neutron). This detector
probe will have 5/10 meter long cable between the moderated Neutron detector and the Electronic
measuring unit. One can preset alarm levels in dose rate / cps / cpm modes. This unit
measures Neutron dose rate in mSv/hr or Flux in CPS/CPM. Dose-rate covered is (0.01 – 10mSv/hr).